ModelAluminum housing with Epoxy Paint316L Stainless Steel housing
TechnologyTransit time ultrasonic flowmeter or ISD/PSD
Signal treatmentAnalogic + ESC (Echo Shape Control)
UsageATEX area compatible (zone 1 and 2)
Max. number of chords12
Measured valuesOptional versions : • Volumetric flowrate, Velocity, Speed of sound, Totalizers, Signal quality, Gain, Transit time… • ISD/PSD
Standard Outputs(2x) isolated 4-20 mA output (active – common grounding)
(2x) isolated contact output (max 50mA – 24V)
Standard Inputs(2x) 4-20 mA (active or passive – common grounding)
(2x) PT100/1000 (2 or 3 wires)
DisplayClear OLED Graphic display 128×64 pixels
Help for diagnosisMulti parameters such as Quality index, Gain, Echo display, Celerity, Transit time.
ConfigurationIntuitive programming with easy to use MMI and keypad
Data loggerLogger of 1,8 GB – 33 M of recorded data-Up to 10 recordable parameters
Recording period adjustable from 1 second to 1 hour
Recording mode adjustable between: Average – Average Min Max – Average Min Max Standard deviation
FiltersDamping time – Memory time – Low-flow cut off
LanguagesFrench – English – German – Spanish – Portuguese – Thaï – Bahasa – Korean – Polish (For more, please contact us)
CommunicationModbus RTU Through RS 485 or HART (as an option)
Modbus TCP Through Ethernet RJ45
USB port for update and logger downloading
Power Supply110 – 230 VAC 50/60Hz or 12 – 24 VDC (average comsumption 6W – 10W peak)
DimensionsL 233 mm x l 226mm x H 141mm (without support)L 308 mm x l 150 mm x H 188 mm
Weight< 7kg< 12kg
ProtectionEN/IEC 60659 IP67
Explosion proofEx db IIC T6 – IECEx INE 22.0016XEx db IIC T6 – IECEx INE 13.0068X
ConformityEMC: EN/IEC 61326-1
Temperature Limits-20 °C to 60°C
Dimensions (millimeters)Minisonic II Ex Aluminum CaseMinisonic II Ex Stainless Steel