Model | Aluminum housing with Epoxy Paint | 316L Stainless Steel housing |
Technology | Transit time ultrasonic flowmeter or ISD/PSD | |
Signal treatment | Analogic + ESC (Echo Shape Control) | |
Usage | ATEX area compatible (zone 1 and 2) | |
Max. number of chords | 1 | 2 |
Measured values | Optional versions : • Volumetric flowrate, Velocity, Speed of sound, Totalizers, Signal quality, Gain, Transit time… • ISD/PSD | |
Standard Outputs | (2x) isolated 4-20 mA output (active – common grounding) (2x) isolated contact output (max 50mA – 24V) | |
Standard Inputs | (2x) 4-20 mA (active or passive – common grounding) (2x) PT100/1000 (2 or 3 wires) | |
Display | Clear OLED Graphic display 128×64 pixels | |
Help for diagnosis | Multi parameters such as Quality index, Gain, Echo display, Celerity, Transit time. | |
Configuration | Intuitive programming with easy to use MMI and keypad | |
Data logger | Logger of 1,8 GB – 33 M of recorded data-Up to 10 recordable parameters Recording period adjustable from 1 second to 1 hour Recording mode adjustable between: Average – Average Min Max – Average Min Max Standard deviation | |
Filters | Damping time – Memory time – Low-flow cut off | |
Languages | French – English – German – Spanish – Portuguese – Thaï – Bahasa – Korean – Polish (For more, please contact us) | |
Communication | Modbus RTU Through RS 485 or HART (as an option) Modbus TCP Through Ethernet RJ45 USB port for update and logger downloading | |
Power Supply | 110 – 230 VAC 50/60Hz or 12 – 24 VDC (average comsumption 6W – 10W peak) | |
Dimensions | L 233 mm x l 226mm x H 141mm (without support) | L 308 mm x l 150 mm x H 188 mm |
Weight | < 7kg | < 12kg |
Protection | EN/IEC 60659 IP67 | |
Explosion proof | Ex db IIC T6 – IECEx INE 22.0016X | Ex db IIC T6 – IECEx INE 13.0068X |
Conformity | EMC: EN/IEC 61326-1 | |
Temperature Limits | -20 °C to 60°C | |
Dimensions (millimeters) | ![]() | ![]() |