Application

Chiller Plant & Mechanical Room

Protect chillers, boilers and pumps, and measure chilled and hot water flow and pressure in central plant rooms.

Measures: Flow · Pressure · Equipment status

Click a number to jump to that measuring point. Conceptual view, not for installation design.
1

Liquid Flow Meters & Flow Switches

Monitors liquid flow in chiller lines, ensuring proper coolant circulation for efficient heat removal.

Dwyer Series IEF Insertion Electromagnetic Flow TransmitterDwyer Series IEF insertion magmeter for 4 to 36 in pipes: 0–6 m/s, ±0.5% of reading at the calibrated velocity, analog, pulse and alarm outputs, BACnet/Modbus option. Dwyer Series TDFS2 Thermal Dispersion Flow Switch (Non-Mechanical, Low Pressure Drop, Large Pipes)Measure Flow Above or Below User Set Flow Rate; Normally-Open & Normally-Closed NPN Outputs; LED Indication Dwyer CP-CN-CT-CX Coolpoint Vortex Meter; Water & Glycol4-20mA, Solid State Relay Output; 316L SS & Brass Body; PEEK Sensor; FKM Seal Ultraflux Minisonic Fixed FlowmeterFaure Herman single-chord clamp-on transit-time ultrasonic flowmeter for liquids, with OLED display, 4-20 mA output, two contact outputs and a 1.8 GB data logger. Ultraflux Uf821 Ultrasonic Fixed FlowmeterFaure Herman fixed clamp-on ultrasonic flowmeter for liquids: up to 4 measuring points per unit, accuracy to 0.5% of reading, on steel, PVC, cast iron or stainless pipes. Ultraflux Uf801P Portable Ultrasonic FlowmeterFaure Herman portable clamp-on ultrasonic flowmeter (Uf801P) for checking liquid flow on any pipe without cutting in: accuracy to 0.5%, multi-layer pipes, 11 stored set-ups. Dwyer Series FS2 Vane Flow Switch for Boilers & Heaters, Adjustable 1-8 in PipesVane Flow Switch for Boilers/Heaters; Reliable Low‑Flow Trip Dwyer Series LFM Flowmeters for GPM & LPM – 3 to 11 in – For Chill & RO Water SystemsPolycarbonate flowmeter with dual, direct reading scales measuring in both GPM and LPM, different scale lengths are available
3

Gas Detection Sensors and Control Panels

Detects hazardous gas leaks, protecting personnel and equipment from dangerous concentrations and ensuring a safe environment.

Application data from the DwyerOmega Application Navigator ↗. Ronsor can help adapt it to your site.

Need help choosing an instrument?

Send us your application details and our engineers will recommend a solution.

Enquiry

Contact Ronsor

Form not working for you? Email us at ronsor@ronsor.com.sg or call +65 6779 2818. We'll use your details only to reply to this enquiry.