Burning zone imaging, kiln shell hot spot detection, flame monitoring, fuel and air flow, and exit gas analysis for lime kilns and other rotary kilns.
Measures: Burning zone temperature · Kiln shell hot spots · Flame monitoring · Fuel gas & air flow · Kiln exit gas O2 / CO
Burning Zone Imaging
Short-wave and mid-wave thermal imaging borescopes at the firing hood show the flame and the burning zone with live temperatures, so firing can be adjusted before the product goes off-spec. High-temperature cameras give a clear visual view of the flame.
NIR-B-640Measuring in a range from 600 to 2000°C (1112 to 3632°F), the NIR-Borescope-640 (NIR-B-640) provides a high-resolution thermal image with real-time, continuous, high-accuracy temperature readings.
MWIR-B-640 Thermal Imaging SolutionCombustion atmospheres using dirty fuels require a thermal imaging solution with advanced spectral filtering and high resolution to deliver clear live images from within a furnace, boiler or incinerator.
ExtremeTemp Furnace CameraCanty EXTREMETEMP™ Cameras are ideal for demanding applications involving visual
Ultratemp High Temperature CameraCanty ULTRATEMP™ Cameras are ideal for demanding applications involving visual inspection or verification in extreme temperature environments.
Kiln Shell Hot Spots
Fixed thermal imagers watch the outside of the rotating shell around the clock and alarm on hot spots that point to refractory damage. Portable pyrometers are used for spot checks.
LWIR 640AMETEK Land LWIR-640 thermal imaging camera measuring 0 to 1000 °C, with a built-in webserver and I/O to run on its own or connect to plant control systems.
Cyclops LAMETEK Land Cyclops L portable, one-handed non-contact pyrometer for spot temperature readings and checking fixed pyrometers, with trigger-controlled data logging.
Flame Monitoring
Compact flame controllers prove the main burner flame to the burner management system, with fibre optic cables where the burner front is hot.
Compact Flame ControllersBFI compact flame controllers that combine flame detection and evaluation in one unit and tell their own burner's flame from neighbouring burners.
Flame Monitoring Fibre Optic CablesBFI glass fibre-optic cables that carry flame radiation to a flame scanner or controller, for hot (up to 600 °C) or high-vibration mounting points.
Fuel Gas & Combustion Air Flow
The kiln uses a lot of fuel. Thermal mass flow meters measure the fuel gas and primary air directly in mass units, so the fuel to air ratio can be held at its most efficient point.
ST100A Flow MeterFCI ST100A thermal mass flow meter for process gases, with 4-20 mA, pulse, HART, FOUNDATION Fieldbus, PROFIBUS or Modbus outputs.
ST80 Flow MeterFCI ST80 thermal mass flow meter for industrial air and gas, with a wide choice of sensors (including wet gas) and process connections.
MT100 Flow MeterFCI MT100 multipoint insertion thermal flow meter with up to eight sensing points, for air and gas flow in stacks, flues and large ducts with short straight runs.
Kiln Exit Gas Analysis
In-situ TDLAS analysers measure O2 and CO at the kiln exit in real time for combustion control, without a sample system to block or maintain.