Analysis & Environment

Gas Detection & Oxygen Analysers

Fixed and portable gas detectors, oxygen analysers and combustion analysers.

Gas detection protects people and plant; gas analysis keeps processes in specification. The right instrument depends on the gas, the concentration range (percent, ppm or ppb) and whether the location is a hazardous area.

Choosing an instrument

  • Car parks and plant rooms (DwyerOmega): carbon monoxide and nitrogen dioxide transmitters such as the Dwyer GSTA/GSTC, CMT200 and CMS300, for ventilation control and alarms.
  • Flammable gas in process areas (Dynament): infrared hydrocarbon sensors and flameproof fixed detectors. Infrared sensing works without oxygen and isn’t poisoned the way catalytic sensors can be.
  • Hydrogen sulphide (AII): the GPR-7100 and GPR-7500 H₂S analysers for biogas and natural gas treatment.
  • Trace oxygen (AII): the ultra-trace oxygen analyser measures down to ppb levels for inerting and high-purity gases.
  • In-situ combustion and emissions gases (NEO Monitors): TDLAS laser analysers measure O₂, CO, NH₃ and other gases directly across a duct or stack.

What to tell us

  • Which gas, and the range: % LEL, % volume, ppm or ppb
  • Safety (people) or process (quality) measurement
  • Ambient or process location, and how the sample reaches the sensor
  • Output, alarm relays and display
  • Area classification and approvals

Instruments are configured to order to these details. See them placed on biogas digesters, cogeneration plants, gas treatment and metering skids and chiller plant rooms.

DwyerOmega

AII GPR-7100 Hydrogen Sulphide (H2S) Analyzer

4-20 mA analog output; Hazardous Area certified

DwyerOmega

AII GPR-7500 (A)IS Hydrogen Sulphide (H2S) Analyzer

certified for use in flammable gas streams; 4-20 mA output, 0-2000 ppmV

DwyerOmega

AII Ultra Trace (ppb) Oxygen Analyzer - AII (Analytical Industries Inc) PI2-MS

Provides Accurate, Stable, and Dependable Oxygen Readings at Both ppb and Low ppm Levels

DwyerOmega

Dwyer Series CMS300 Carbon Monoxide Transmitter & Switch (0 to 300 PPM)

Selectable Current or Voltage Output; Jumper Selectable SPDT Relay Contact

DwyerOmega

Dwyer Series CMT200 Carbon Monoxide Transmitter (0 to 200 PPM)

Selectable Current or Voltage Output, Electrochemical Sensor

DwyerOmega

Dwyer Series GSTA/GSTC Carbon Monoxide & Nitrogen Dioxide Gas Transmitters

Electrochemical Sensor; Universal Current & Voltage Outputs; Optional Modbus & BACnet Communications & Display

DwyerOmega

Dwyer Series GSTA/GSTC-D Carbon Monoxide & Nitrogen Dioxide Duct Mounted Gas Transmitter

Electrochemical Sensor; Universal Current & Voltage Outputs; Optional Modbus & BACnet Communications & Display

DwyerOmega

Dynament FGD10A Flameproof Fixed Gas Detectors

Ex d gas detector with 3 alarm relays; non-intrusive mag-pen menu; detects hydrocarbons, hydrogen, or toxic gases.

DwyerOmega

Dynament FGD10B Flameproof Fixed Gas Detectors

Ex d gas detector in IP65 aluminium / SS housing; accepts plug-in handheld configurator; detects hydrocarbons, hydrogen, or toxic...

DwyerOmega

Dynament Platinum Series - Hydrocarbon Infrared Gas Sensors

Platinum IR Hydrocarbon Sensor; Measures CH₄ from 0‑100%v

DwyerOmega

Dynament Standard Series - Hydrocarbon Infrared Sensors

Standard IR Hydrocarbon Sensor; 4-20mA output, Measures CH₄ from 0‑100%v

Need help choosing an instrument?

Send us your application details and our engineers will recommend a solution.

Enquiry

Contact Ronsor