Process Vessels & Skids

Distillation Columns & Process Vessels

Level, pressure, flow and temperature measurement, overpressure protection, sampling and vessel viewing for columns, reactors, separators and drums.

Measures: Level & interface · Pressure & differential pressure · Flow · Temperature · Overpressure protection · Sampling · Vessel viewing

1

Column & Vessel Level

Magnetostrictive and guided wave radar transmitters measure level and interface in columns, reflux drums and separators. Magnetic and reflex level gauges give a local reading, and side-mounted level switches give independent high and low level alarms on vessels and separator packages.

LMT100 Magnetostrictive Level TransmitterABB K-TEK LMT100 in-tank magnetostrictive level transmitter for total and interface level to 0.01% of full scale, probes to 22 m, pressures to 165 bar. MW05 Magwave Dual ChamberABB K-TEK MagWave dual-chamber level gauge: one chamber for the indicator float and one for a guided wave radar probe, for local and remote level from one installation. KM26 Magnetic Level GaugeABB K-TEK KM26 magnetic level gauge: a float drives a highly visible indicator with no process fluid touching glass, for toxic, corrosive, high-pressure or hot service. LMS100 Magnetic Level Gauge SwitchABB LMS100 magnetically operated SPDT switch that mounts on a KM26 magnetic level gauge or float chamber to signal a high or low level. LMS200 Magnetic Level Gauge SwitchABB LMS200 latching level switch with two snap-action switches, operated as the float of a KM26 magnetic level gauge passes it. Reflex Level GaugesSimco reflex glass level gauges for boilers, vessels and tanks: prismatic glass shows the liquid as black against a bright vapour space, for a clear local reading. Side Mount Level Switch With ChamberSOR sealed-chamber level switches, a lower-cost alternative to flanged models, designed to ASME B31.3 and B31.1 for up to 207 bar and 649 °C. 1510 Side Mounted Level SwitchSOR 1510 side-mounted float level switch with manual check, for vacuum to 345 bar and -40 to 204 °C, explosion-proof or intrinsically safe. 1540 Non-Bleed Pneumatic Level Switchvac to 1500 psi, vac to 100 bar; -40° to 400°F, -40° to 204°C Maximum process pressure 60 SCFH (1.7 CMH)

Application stories

Need help choosing an instrument?

Send us your application details and our engineers will recommend a solution.

Enquiry

Contact Ronsor