Process Vessels & Skids
Distillation Columns & Process Vessels
Level, pressure, flow and temperature measurement, overpressure protection, sampling and vessel viewing for columns, reactors, separators and drums.
Measures: Level & interface · Pressure & differential pressure · Flow · Temperature · Overpressure protection · Sampling · Vessel viewing
Column & Vessel Level
Magnetostrictive and guided wave radar transmitters measure level and interface in columns, reflux drums and separators. Magnetic and reflex level gauges give a local reading, and side-mounted level switches give independent high and low level alarms on vessels and separator packages.
LMT100 Magnetostrictive Level TransmitterABB K-TEK LMT100 in-tank magnetostrictive level transmitter for total and interface level to 0.01% of full scale, probes to 22 m, pressures to 165 bar.
MW05 Magwave Dual ChamberABB K-TEK MagWave dual-chamber level gauge: one chamber for the indicator float and one for a guided wave radar probe, for local and remote level from one installation.
KM26 Magnetic Level GaugeABB K-TEK KM26 magnetic level gauge: a float drives a highly visible indicator with no process fluid touching glass, for toxic, corrosive, high-pressure or hot service.
LMS100 Magnetic Level Gauge SwitchABB LMS100 magnetically operated SPDT switch that mounts on a KM26 magnetic level gauge or float chamber to signal a high or low level.
LMS200 Magnetic Level Gauge SwitchABB LMS200 latching level switch with two snap-action switches, operated as the float of a KM26 magnetic level gauge passes it.
Reflex Level GaugesSimco reflex glass level gauges for boilers, vessels and tanks: prismatic glass shows the liquid as black against a bright vapour space, for a clear local reading.
Side Mount Level Switch With ChamberSOR sealed-chamber level switches, a lower-cost alternative to flanged models, designed to ASME B31.3 and B31.1 for up to 207 bar and 649 °C.
1510 Side Mounted Level SwitchSOR 1510 side-mounted float level switch with manual check, for vacuum to 345 bar and -40 to 204 °C, explosion-proof or intrinsically safe.
1540 Non-Bleed Pneumatic Level Switchvac to 1500 psi, vac to 100 bar; -40° to 400°F, -40° to 204°C Maximum process pressure 60 SCFH (1.7 CMH)
Pressure & Differential Pressure
Pressure transmitters control column pressure, and differential pressure across the trays or packing warns of flooding.
Dwyer Series-3100D Smart Differential Pressure Transmitter, HART®, Hazardous AreaDwyer (Mercoid) 3100D explosion-proof smart differential pressure transmitter: ±0.075% accuracy, 100:1 turndown, HART, for flow, level and filter DP in hazardous areas.
Dwyer Series-3200G Explosion-Proof Pressure Transmitter, HART®, FM Approved, 100:1 RangeDwyer (Mercoid) 3200G explosion-proof smart gauge pressure transmitter: ±0.075% accuracy, 100:1 turndown, HART, ranges to 8500 psi, FM approved.
Omega PX880 Industrial, Intrinsically Safe Pressure TransmittersOmega PX880 industrial pressure transmitter in welded 316 SS: ±0.2% accuracy, 4-20 mA, 5:1 turndown, FM and CSA intrinsically safe and explosion-proof.
Omega Series PX835 Intrinsically Safe Pressure Transmitters with ATEX RatingOmega PX835 pressure transmitter for hazardous areas: explosion-proof, ATEX flameproof and intrinsically safe, vacuum to 10,000 psi, ±0.5% accuracy, 4-20 mA.
Omega PX509-IS High Accuracy, Intrinsically Safe Pressure TransmittersOmega PX509-IS intrinsically safe pressure transmitter: ±0.08% accuracy, 4-20 mA, FM approved for Class I-III Div 1 and Zone 0, 316L wetted parts.
Feed, Reflux & Product Flow
Vortex and swirl meters suit steam, gases and light liquids, and wedge elements handle the heavy, viscous bottoms.
FSV430/FSV450 VortexmasterABB VortexMaster vortex flowmeters for gas, liquid and steam; the FSV450 adds an input for steam mass or energy flow. HART, Modbus, PROFIBUS PA or FOUNDATION Fieldbus.
FSS430/FSS450 SwirlmasterABB SwirlMaster swirl flowmeters for gas, liquid and steam; the FSS450 adds an input for mass or energy flow. HART, Modbus, PROFIBUS PA or FOUNDATION Fieldbus.
FPD470 Wedge Flow ElementFPD470 wedge elements consists of a body and wedge flow restriction. This restriction creates a differential pressure in proportion to the square of the volumetric flow rate.
Dwyer Series 3100MP Smart Pressure Transmitter for Flow & LevelDwyer (Mercoid) 3100MP smart differential pressure transmitter for flow and level: ±0.075% accuracy, 100:1 rangeability, HART, explosion-proof Class I Div 1.
Temperature
RTD and thermocouple assemblies in thermowells measure vessel and column temperatures, including on separator packages.
Temperature Sensor and ThermowellsThe 1400 Series Temperature Sensor Assemblies are general purpose assemblies that can be used in a variety of applications.
Dwyer Series TTE Explosion-Proof RTD Temp Transmitter, -30 to 250 °F, Easy Adjust, Offshore HVACExplosion‑Proof RTD Temperature Transmitter; 4‑20 mA Output
Overpressure Protection
Spring-loaded safety relief valves protect columns and vessels from overpressure. Where a rupture disc sits under a relief valve, a pressure switch in the space between them signals that the disc has burst or is leaking.
Model 64 Safety Relief ValvesBS&B Model 6400 spring-loaded, full-nozzle angle safety relief valves with flanged connections: conventional, bellows-balanced or balanced-piston, for gas, steam and liquid.
Model 51 Safety Relief ValvesThe model 3-5111 is an angular type safety relief valve at 90º between the inlet and outlet connections. It is supplied with threaded or flanged connections, full nozzle, direct action, spring loaded, with full lift and fast opening.
Sub Mini Hermet8 to 200 psi, 0.5 to 14 bar (adjustable); 0.6 to 500 psi, 0.4 to 35 bar (factory set)
Process Sampling
Closed sampling systems take representative samples of light and heavy products without exposing the operator or releasing vapours.
Inline Sampling SystemSENSOR inline grab sampling system (ISS) built into a spool piece, sampling without a fast loop; suits high-temperature and high-viscosity service.
Heavy Products Sampling SystemThe SENSOR Heavy Products Sample System (HPSS) is designed to collect samples of hot, heavy products (such as resid, asphalt, hot tar, gas oil, resins, slurries, surfactants and emulsions) while maintaining personnel safety.
RAM Sampling SystemSENSOR RAM sampling system (RSS) that mounts on the side of a tank or pipeline, with a piston valve for viscous or particle-laden fluids that plug other valves.
Inline Valve Sampling SystemSENSOR inline valve sampling system (IVSS) that fits straight into 1, 2 or 3 in process piping and takes closed-loop samples without a pressure differential.
Sight Glasses & Vessel Viewing
Fused glass sight glasses and lights let operators see inside vessels and reactors safely, and process cameras show the view in the control room.
Fuseview Sight GlassCanty Fuseview fused-glass sight windows with Factory Mutual approval, for safe high-pressure viewing into tanks, reactors and pipelines.
Fuseview LightsCanty fibre-optic vessel lights that carry high-output halogen light through a sight glass, so one port can be used for both lighting and viewing.
Process CameraCanty process camera and lighting system that views inside a pressure or process vessel through a single connection as small as 2 in, with Ethernet video to the control room.
Purge & Small Flows
Variable area purgemeters set and show the small purge flows that keep instrument impulse lines clear.
FAM3200 Armoured PurgemeterABB FAM3200 armoured purgemeter for small gas and liquid flows, for opaque or aggressive fluids or wherever a glass tube can't be used.
FGM6100 Glass Tube PurgemasterABB Purgemaster FGM6100 glass tube variable area flowmeter for low liquid and gas flows, with a stainless steel body and an operator protection shield.
Valve Position
Valve position indicators and transmitters confirm that valves are open or closed.