TG40 High Energy Flare Pilot Torch with FFG
Flare tip pilot burner with high energy igniter, redundant thermocouple flame detection and Flame Front Generator (FFG) connection.
Supplied and supported in Singapore by Ronsor Engineering · +65 6779 2818 · Not sure it's the right one? Try the Product Finder
The TG40 pilot torch is built for flare tips. It combines a high energy ignition rod, redundant thermocouples for flame detection and an outlet for a Flame Front Generator (FFG), so it can be used for new flares or to retrofit and upgrade existing FFG systems. Together with the re-ignition control box it keeps the flare reliably lit.
Features
- High energy igniter (up to Ø17 mm) or high voltage electrode, unaffected by humidity, water and dirt
- Integrated flame detection for automatic re-ignition
- FFG retrofit and upgrade capability
- Induced (Venturi) or forced draft air configuration
- Straight or angled outlet; length and shape made to order
| Specification | |
|---|---|
| Reference code | TG40/L… (tube length on demand) |
| Tube outer diameter | 42.2 mm (1¼") |
| Outlet design | Straight or angled |
| FFG connection | Threaded or flanged to customer specification |
| Gas connection | G 3/8 |
| Air flow | Induced draft (Venturi) |
| Gas flow rate | 1.8 – 2.5 Nm³/h |
| Gas pressure | 0.2 – 0.4 atm |
| Ignition rod | High energy igniter up to Ø17 mm |
| Flame detection | Redundant thermocouples |